Hot Keywords:Variable Speed Drives, soft starters, motors, intelligent robots, and power modules

Scan your phone once
·Linear acceleration of the motor and load
·Reduced mechanical stress on the motor shaft, load and drive train
·Ramp profiling to better match the type of load
·Reduce or limit motor starting currents
·Eliminate voltage dips on supply during motor starting
·Eliminate belt squeal during starting fans
·Provide better control of pump motors to eliminate water hammer related problems
·Increased motor efficiency during acceleration and deceleration
·No instability issues due to changing power factor
·No tachometers or external speed feedback devices required
·Comply with local supply authority requirements regarding the starting of an electric motor
·Avoid high starting currents and current peaks which often make it necessary to increase supply capacity
·Greater protection for the motor, load and soft starter
·Comes with user-adjustable dual operation modes: continuous (no bypass ) and bypass
·Smaller in size than specialized soft starters for mining equipment, it offers a higher cost-performance ratio and is suitable for applications with limited installation space, as well as for light loads such as fans and water pumps
1. It comes with user adjustable dual operation modes, Continuous and Bypass mode. In case of bypass failure, it can be manually switched to continuous load mode to ensure normal production.
2. Continuous load mode, no need for internal or external bypass AC contactors, soft start is used as a frequency converter to reduce costs and failure rates
3. The soft starter has the function of anti shaking low voltage maintenance to deal with the problem of low voltage during the start-up of surrounding large equipment: during AC control, the three-phase voltage drops to 38% of the rated voltage without fault shutdown, and during DC control, it drops to 28% without fault shutdown, and can be set to shield three-phase imbalance faults. If the bypass operation mode is adopted, it is necessary to consider whether the bypass AC contactor used has a low voltage holding function. Under continuous load mode, bypass AC contactors do not need to be considered
4. The soft starter provides excellent soft start and soft stop, and can choose voltage ramp or torque control ramp. The Smartstart 6000 includes SMART-TORQ, a unique "torque control system" developed in Australia to achieve linear acceleration of motor speed. The SmartStart 6000 combines excellent torque control system with robust design, suitable for all types of loads and applications. The mass of radiators with temperature controlled ventilation is a standard feature that can adapt to more demanding (heavy-duty) applications and higher hourly start-up rates

Previous:Soft starter dedicated to bucket wheel machine/belt conveyor/twin bucket